Dynamic Infusion compensates for intraocular pressure fluctuations, allowing surgeons to maintain IOP near physiological levels while preserving stable intraocular conditions, even during high vacuum and flow settings. The system supports gravity-controlled passive infusion, air-driven active infusion, and Dynamic Infusion, and is compatible with both SPEEP and peristaltic pumps.
-
PACS automatically regulates phaco tip movement in real time to maintain consistent longitudinal motion regardless of lens density. By adapting energy delivery dynamically, PACS improves emulsification efficiency while reducing the need for constant manual pedal adjustments during cataract surgery.
-
The Power LED Plus illumination system features adjustable color spectrum and light intensity for enhanced visualization during posterior segment surgery. Surgeons can customize yellow and blue light balance to improve tissue contrast and visibility while minimizing phototoxic exposure. The lighting system is compatible with both standard and 3D microscopes.
-
easyVit enables simultaneous dual-linear control of aspiration and cut rate through a single foot pedal movement. The customizable pedal pathway supports smooth transitions across different vitrectomy phases without requiring program changes, improving workflow efficiency during posterior segment procedures.
-
The adjustable nine-step laser aiming beam provides clear and customizable visualization for both standard and 3D microscope systems, supporting precise targeting and surgeon preference optimization.
-
The Caliburn Trocar System features a sharp lance-shaped blade and bevelled cannula design that reduce penetration force by up to 43%, enabling smoother trocar insertion and improved surgical handling. Tactile handle markings support quick orientation during procedures.
-
The Continuous Flow Cutter maintains constant aspiration through a permanently open port, reducing retinal traction while improving vitreous removal efficiency. With cut rates up to 15,000 cpm and enhanced stiffness, the cutter delivers stable and powerful vitreoretinal performance.
New Caliburn Trocar System
Smooth trocar placement with high cutting force.
Sharp lance-shaped blade for efficient scleral penetration.
Bevelled cannula design reduces penetration force by up to 43%.
Tactile handle markings for quick orientation.
Redesigned packaging reduces waste per trocar set by 30%.
New Continuous Flow Cutter
Constant flow. Stability when it matters.
61% increased aspiration flow at 23G for faster vitreous removal.
81% increased stiffness at 27G for enhanced stability.
Combines continuous aspiration, advanced fluidics, and up to 15,000 cpm for powerful surgical performance.