MicroSurgical Technology Capsule Retractors

SGD 0.00

The MicroSurgical Technology Capsule Retractors are designed for intraoperative management of weakened or compromised zonules during cataract surgery.

Inserted similarly to iris hooks, the retractors stabilize the capsular bag by acting as artificial zonules throughout the procedure. Their specialized design provides enhanced support at the capsular equator, helping surgeons maintain stability and control during challenging cases.

The MST Capsule Retractors feature broad capsule contact areas for gentle tissue handling, while the double-banded nylon construction improves lateral stability and ease of insertion.

The Chang Modification version further enhances compatibility with capsular tension rings (CTR) by minimizing the risk of entanglement and improving positioning during retraction.

The MicroSurgical Technology Capsule Retractors are designed for intraoperative management of weakened or compromised zonules during cataract surgery.

Inserted similarly to iris hooks, the retractors stabilize the capsular bag by acting as artificial zonules throughout the procedure. Their specialized design provides enhanced support at the capsular equator, helping surgeons maintain stability and control during challenging cases.

The MST Capsule Retractors feature broad capsule contact areas for gentle tissue handling, while the double-banded nylon construction improves lateral stability and ease of insertion.

The Chang Modification version further enhances compatibility with capsular tension rings (CTR) by minimizing the risk of entanglement and improving positioning during retraction.

  • Unlike standard iris hooks that only engage the capsulorhexis margin, MST Capsule Retractors feature extended posterior tabs designed to reach the equator of the capsular bag. This provides improved intraoperative stability and support for eyes with compromised zonules.

  • The retractors incorporate a looped distal end on the posterior tab, creating a broader area of contact with the capsule. This design helps distribute tension more evenly and minimizes the risk of capsule puncture during surgery.

  • Constructed from double-banded nylon, the retractors provide enhanced lateral stability for smoother placement and improved handling throughout the procedure.

  • The Chang Modification version features a closed-loop posterior tab design that reduces the risk of entanglement with capsular tension rings while maintaining broad capsule contact and easy insertion.

    Its adjusted geometry allows the posterior portion of the retractor to remain parallel to the iris plane during retraction, helping prevent unwanted movement toward the incision site.

 