Huvitz HNT-1/1P Non-Contact Tonometer

SGD 0.00

The Huvitz HNT-1 / HNT-1P Non-Contact Tonometer is a non-contact tonometry system designed to provide comfortable intraocular pressure measurement with intelligent puff control, accurate corneal compensation, and efficient clinical workflow.

Featuring smart auto-adjustable puffing technology, the HNT-1 / HNT-1P automatically adjusts air pressure based on the patient’s intraocular pressure to improve examination comfort while maintaining reliable measurement accuracy. The intuitive interface supports corneal thickness-based IOP compensation for more accurate glaucoma assessment and ocular evaluation.

The HNT-1P model additionally integrates pachymetry and anterior chamber angle visualization functions for expanded diagnostic capability.

The Huvitz HNT-1 / HNT-1P Non-Contact Tonometer is a non-contact tonometry system designed to provide comfortable intraocular pressure measurement with intelligent puff control, accurate corneal compensation, and efficient clinical workflow.

Featuring smart auto-adjustable puffing technology, the HNT-1 / HNT-1P automatically adjusts air pressure based on the patient’s intraocular pressure to improve examination comfort while maintaining reliable measurement accuracy. The intuitive interface supports corneal thickness-based IOP compensation for more accurate glaucoma assessment and ocular evaluation.

The HNT-1P model additionally integrates pachymetry and anterior chamber angle visualization functions for expanded diagnostic capability.

Smart Puffing Control for Comfortable IOP Measurement

The intelligent puffing control system automatically adjusts air pressure according to the patient’s intraocular pressure. Once sufficient measurement data is acquired, the air delivery stops automatically to help reduce patient discomfort during examination.

 

Automatic 3D Tracking & Guidance System

Automatic 3D tracking and focusing simplify alignment during measurement. Animated on-screen guidance assists users with joystick and chin rest adjustments when positioning falls outside the auto-tracking range.

 

Accurate IOP & Corneal Thickness Compensation

The HNT-1 supports compensated intraocular pressure measurement by allowing manual input of corneal thickness values. The HNT-1P includes an integrated pachymeter that automatically measures corneal thickness and immediately displays compensated IOP results.

Corneal Thickness Visualization (HNT-1P)

The HNT-1P provides cross-sectional visualization of corneal thickness measurements, supporting detailed bilateral corneal assessment and improved clinical interpretation.

 

Anterior Chamber Angle Analysis Function (HNT-1P)

The built-in ACA cross-sectional imaging function on the HNT-1P assists in evaluating anterior chamber angle conditions and supports glaucoma-related assessments, including angle-closure evaluation.

 

Enquire Now